Contact

buffer tank

JPSR 1250 · without insulation

JPSR Type 1250 · High-Performance Solar Buffer Tanks

Item No. 1111250

  • Tanks without insulation
nominal capacity
1246
Ø without insulation
950 mm
Height
2,010 mm
Weight
210 kg

Request for 1111250

EAN 4250659500598

Average of JPSR Type 1250

Dimensions and weights

H 2,010 Ø 950 E I H G J F K
Ø without insulation
950 mm
Height
2,010 mm
tilt height
2,070 mm
Weight
210 kg

Connections

Letters as shown in the illustration

Letter connection Height Size Thread Angle
K Heating Return Index RL 300 mm 1¼" Female thread 30.2°
E Connection 1 310 mm 1½" Female thread 12.1°
E Connection 1 310 mm 1½" Female thread 112.1°
E sensor sleeve 310 mm ½" Female thread 94°
F Connection 2 745 mm 1½" Female thread 12.1°
F Connection 2 745 mm 1½" Female thread 112.1°
F sensor sleeve 745 mm ½" Female thread 94°
J Heating flow line Index flow 1,015 mm 1¼" Female thread 30.2°
G Connection 3 1,250 mm 1½" Female thread 12.1°
G Connection 3 1,250 mm 1½" Female thread 112.1°
G sensor sleeve 1,250 mm ½" Female thread 94°
H Connection 4 1,710 mm 1½" Female thread 12.1°
H Connection 4 1,710 mm 1½" Female thread 112.1°
H sensor sleeve 1,710 mm ½" Female thread 94°
I Top connection 2,010 mm 1½" Female thread 0°

Technical Specifications

Volume

nominal capacity
1246

heat exchanger

Heat exchanger Bottom Surface
3.1 m²

Print

Operating pressure of storage tanks
3 bar
Test pressure of the storage tank
4.5 bar
Max. Pressure heat exchanger
6 bar

specification text

ENERGY BUFFER TANK

Buffer tank for all hot water central heating systems. Suitable for: solid fuel and oil-fired boilers, heat pumps, solar systems, and gas or electric instantaneous water heaters. Manufactured from high-quality S235JR steel in accordance with EN 10025 and EC Directive 97/23/EC; exterior with anti-corrosion coating, interior left unfinished. Includes a sensor terminal strip for variable positioning of the sensors.

Nominal capacity
1246 L
Operating pressure of storage tanks
3 bar
Test pressure of the storage tank
4.5 bar
Minimum pressure in the storage tank
+0 bar
Max. operating temperature
95°C
Min. temperature
20 °C
Heat exchanger Bottom Surface
3.1 m²
Max. Pressure heat exchanger
6 bar

Features

  • 4 x 1½" sockets (system connection on the left)
  • 4 x 1½" sockets (system connection on the right)
  • System connections, including layer baffle plate
  • 1 x 1½" socket (air vent)
  • 4 x ½" sockets (standard sockets)
  • 2 x 1" Socket (heat exchanger)

The system connection ports are spaced 100° apart. Dimensions without insulation: 950 x 2010 (Ø x H) mm

Manufacturer
Juratherm GmbH
Match Code
JPSR 1250
Weight
~204 kg
Tilt height
2070 mm
EAN13
4250659500598

Product video