Contact

buffer tank

JPSR 1250 · without insulation

JPSR Type 1250 · High-Performance Solar Buffer Tanks

Item No. 1111250

  • Tanks without insulation
nominal capacity
1246
Ø without insulation
950 mm
Height
2,010 mm
Weight
204 kg
Tank 1111250 In stock

As of Oct 28, 2026

Request for 1111250

EAN 4250659500598

Average of JPSR Type 1250

Dimensions and weights

H 2,010 Ø 950 E I H G J F K
Ø without insulation
950 mm
Height
2,010 mm
tilt height
2,070 mm
Weight
204 kg

Connections

Letters as shown in the illustration

Letter connection Height Size Thread Angle
K Heating Return Index RL 300 mm 1¼" Female thread 30.2°
E Connection 1 310 mm 1½" Female thread 12.1°
E Connection 1 310 mm 1½" Female thread 112.1°
E sensor sleeve 310 mm ½" Female thread 94°
F Connection 2 745 mm 1½" Female thread 12.1°
F Connection 2 745 mm 1½" Female thread 112.1°
F sensor sleeve 745 mm ½" Female thread 94°
J Heating flow line Index flow 1,015 mm 1¼" Female thread 30.2°
G Connection 3 1,250 mm 1½" Female thread 12.1°
G Connection 3 1,250 mm 1½" Female thread 112.1°
G sensor sleeve 1,250 mm ½" Female thread 94°
H Connection 4 1,710 mm 1½" Female thread 12.1°
H Connection 4 1,710 mm 1½" Female thread 112.1°
H sensor sleeve 1,710 mm ½" Female thread 94°
I Top connection 2,010 mm 1½" Female thread 0°

Technical Specifications

Volume

nominal capacity
1246

heat exchanger

Heat exchanger Bottom Surface
3.1 m²

Print

Operating pressure of storage tanks
3 bar
Test pressure of the storage tank
4.5 bar
Max. Pressure heat exchanger
6 bar

specification text

ENERGY BUFFER TANK

Buffer tank for all hot water central heating systems. Suitable for: solid fuel and oil-fired boilers, heat pumps, solar systems, and gas or electric instantaneous water heaters. Manufactured from high-quality S235JR steel in accordance with EN 10025 and EC Directive 97/23/EC; exterior with anti-corrosion coating, interior left unfinished. Includes a sensor terminal strip for variable positioning of the sensors.

Nominal capacity
1246 L
Operating pressure of storage tanks
3 bar
Test pressure of the storage tank
4.5 bar
Minimum pressure in the storage tank
+0 bar
Max. operating temperature
95°C
Min. temperature
20 °C
Heat exchanger Bottom Surface
3.1 m²
Max. Pressure heat exchanger
6 bar

Features

  • 4 x 1½" sockets (system connection on the left)
  • 4 x 1½" sockets (system connection on the right)
  • System connections, including layer baffle plate
  • 1 x 1½" socket (air vent)
  • 4 x ½" sockets (standard sockets)
  • 2 x 1" Socket (heat exchanger)

The system connection ports are spaced 100° apart. Dimensions without insulation: 950 x 2010 (Ø x H) mm

Manufacturer
Juratherm GmbH
Match Code
JPSR 1250
Weight
~204 kg
Tilt height
2070 mm
EAN13
4250659500598

Product video

JPSR 1250 in motion