buffer tank
JPSL 2000 · Ecoline Vlies silver
Efficiency Class C
JPSL Type 2000 V2, assembled, silver · Includes 130 mm fleece insulation
Item No. 840438
- heat loss
- 166 W
- Standby loss
- 3.99 kWh/24 h
- ErP Volume
- 2,010
- Weight
- 229 kg
As of Oct 28, 2026
EAN 4250659513291
Dimensions and weights
- Ø with insulation
- 1,360 mm
- Ø without insulation
- 1,100 mm
- Height including insulation
- 2,470 mm
- Height without insulation
- 2,370 mm
- tilt height
- 2,420 mm
- Weight
- 229 kg
- Insulation thickness
- 130 mm
Connections
No connections have been specified for this tank yet.
Technical Specifications
Volume
- nominal capacity
- 2010
- Operating pressure of storage tanks
- 3 bar
- Test pressure of the storage tank
- 4.5 bar
insulation
- Insulation thickness of the jacket (assembled)
- 130 mm
- Insulation thickness of the jacket (raw)
- 145 mm
- Insulation thickness of the lid
- 150 mm
- Insulation color
- silver
- Lambda
- 0.0388 W/mK
- Bulk density
- 2340 g/m²
- Fire rating
- B2 according to DIN 4102
Energy (ErP)
- ErP Class
- C
- ErP - Heat loss (W)
- 166 W
- ErP – Heat Loss (kWh)
- 3.99 kWh
- ErP - Contents
- 2010
specification text
ENERGY BUFFER TANK, incl. insulation with stratification charging system, resulting in significantly improved stratification behavior
Buffer tank for all hot water central heating systems. Suitable for: solid fuel and oil-fired boilers, heat pumps, solar systems, and gas or electric instantaneous water heaters. Manufactured from high-quality S235JR steel in accordance with EN 10025 and EC Directive 97/23/EC; exterior with anti-corrosion coating, interior left unfinished. Includes a sensor terminal strip for variable positioning of the sensors.
- Nominal capacity
- 2010 L
- Operating pressure of storage tanks
- 3 bar
- Test pressure of the storage tank
- 4.5 bar
- Minimum pressure in the storage tank
- +0 bar
- Max. operating temperature
- 95°C
- Min. temperature
- 20 °C
Features
- 1 x 1½" socket (air vent)
- 5 x 2" socket (system connection on the left)
- 5 x 2" sockets (system connection on the right)
- 2 x deflector plates
- 2 x mitered pipe DN 50
- 2 x return layer ducts
- 5 x ½" sockets (standard sockets)
- 1 x perforated sheet, 50%
The system connection ports are spaced 100° apart.
Insulation Details
- Material
- Polyester fiber nonwoven
- Insulation color
- Silver
- Insulation thickness of the jacket (assembled)
- 130 mm
- Lambda
- 0.0388 W/mK
- Fire rating
- B2 according to DIN 4102
- Temperature Resistance
- 110 °C
- Bulk density
- 2340 g/m²
- Includes 50 mm floor insulation
- ErP Class
- C
- ErP - Heat loss (W)
- 166 W
Dimensions with insulation
- 1360 x 2470 (Ø x H) mm
- Manufacturer
- Juratherm GmbH
- Match Code
- JPSL 2000 V2 silver
Assembly consisting of
- JPSL Type 2000 V2
- Fleece insulation Type 2000
- Weight
- ~229 kg
- Tilt height
- 2420 mm
- EAN13
- 4250659513291
Composition
- 1562000 JPSL Type 2000 V2 tank · Buffer tanks with stratification charging system
- 9972000 Fleece insulation Type 2000 insulation · JPSM/R/RR 130mm silver
Product video
JPSL 2000 in motion
Downloads
Energy label required only for tanks up to 500 liters