V4A Stainless Steel
JEBS2 1000 · silver
Efficiency Class C
JEBS2 Type 1000 · Solar Stainless Steel Storage Tanks
Item No. 5021000
- heat loss
- 140 W
- Standby loss
- 3.36 kWh/24 h
- ErP Volume
- 990
- Weight
- 200 kg
Tank 5021000 Delivery time: approx. 11–13 weeks
As of Oct 28, 2026
EAN 4250659501991
Dimensions and weights
- Ø with insulation
- 850 mm
- Height including insulation
- 1,980 mm
- tilt height
- 2,050 mm
- Weight
- 200 kg
- Insulation thickness
- 100 mm
Connections
No connections have been specified for this tank yet.
Technical Specifications
Volume
- nominal capacity
- 990
heat exchanger
- Heat exchanger Bottom Surface
- 2.4 m²
- Heat exchanger Top Surface
- 1.8 m²
- Performance metric below
- 54
- Key performance indicator above
- 24
- Operating pressure of storage tanks
- 10 bar
- Max. Pressure heat exchanger
- 25 bar
insulation
- Insulation thickness of the jacket (assembled)
- 100 mm
- Insulation color
- silver
Energy (ErP)
- ErP Class
- C
- ErP - Heat loss (W)
- 140 W
- ErP – Heat Loss (kWh)
- 3.36 kWh
- ErP - Contents
- 990
Miscellaneous
- Bottom flange
- 120/180 mm
specification text
The JEBS 2 is a vertical, indirectly heated solar water storage tank. Suitable for: solid-fuel and oil-fired boilers, solar thermal systems, gas or electric instantaneous water heaters, as well as solar systems. Made of V4A 1.4571 stainless steel, fully immersion-pickled and passivated.
- Nominal capacity
- 990 L
- Operating pressure of storage tanks
- 10 bar
- Min. operating pressure of the storage tank
- 0 bar
- Max. operating temperature
- 95°C
- Min. Temperature
- 4 °C
- 100 mm Neodul insulation is removable!
- Insulation color
- Silver
- ErP Class
- C
- ErP - Heat loss (W)
- 140 W
- Heat exchanger Top Surface
- 1.8 m²
- Heat exchanger Bottom Surface
- 2.4 m²
- Max. Pressure heat exchanger
- 25 bar
- Bottom flange
- 120/180 mm
Dimensions without insulation
- 850 x 1980 (Ø x H) mm
- Manufacturer
- Juratherm GmbH
- Match code
- JEBS2 1000 silver
- Weight
- ~200 kg
- Tilt height
- 2050 mm
- EAN13
- 4250659501991
Downloads
Energy label required only for tanks up to 500 liters