Contact

buffer tank

JPSLR 825 · Neodul® silver

Efficiency Class B

JPSLR Type 825 V2, assembled, silver · Includes 130 mm Neodul® insulation

Item No. 840367

  • Assembled tank
heat loss
83 W
Standby loss
1.99 kWh/24 h
ErP Volume
718
Weight
256 kg
Tank 157825 Delivery time: approx. 4–6 weeks
Insulation 9720825 In stock
Total Delivery time: approx. 4–6 weeks

As of Oct 28, 2026

Request for 840367

EAN 4250659510443

Average of JPSLR Type 825 V2, assembled, silver

Dimensions and weights

H 1,790 Ø 1,050
Ø with insulation
1,050 mm
Ø without insulation
790 mm
Height including insulation
1,790 mm
Height without insulation
1,693 mm
tilt height
1,740 mm
Weight
256 kg
Insulation thickness
130 mm

Connections

No connections have been specified for this tank yet.

Technical Specifications

Volume

nominal capacity
694

heat exchanger

Heat exchanger Bottom Surface
2.8 m²
WT Content at the bottom
19.6

Print

Heat exchanger Pressure drop at the bottom
248 mbar
Operating pressure of storage tanks
4.5 bar
Test pressure of the storage tank
7.8 bar
Max. Pressure heat exchanger
6 bar

insulation

Insulation thickness of the jacket (assembled)
130 mm
Insulation color
silver
Fire rating
B2 according to DIN 4102

Energy (ErP)

ErP Class
B
ErP - Heat loss (W)
83 W
ErP – Heat Loss (kWh)
1.99 kWh
ErP - Contents
718

specification text

ENERGY BUFFER TANK with 1 heat exchanger, including insulation with a stratification charging system, resulting in significantly improved stratification behavior

Buffer tank for all hot water central heating systems. Suitable for: solid fuel and oil-fired boilers, heat pumps, solar systems, and gas or electric instantaneous water heaters. Manufactured from high-quality S235JR steel in accordance with EN 10025 and EC Directive 97/23/EC; exterior with anti-corrosion coating, interior left unfinished. Includes a sensor terminal strip for variable positioning of the sensors.

Nominal capacity
694 L
Operating pressure of storage tanks
4.5 bar
Test pressure of the storage tank
7.8 bar
Minimum pressure in the storage tank
+0 bar
Max. operating temperature
95°C
Min. temperature
20 °C
Heat exchanger Bottom Surface
2.8 m²
WT Content at the bottom
19.6 L
Heat exchanger Pressure drop at the bottom
248 mbar
Max. Pressure heat exchanger
6 bar

Features

  • 1 x 1½" socket (air vent)
  • 5 x 1 ½ " socket (system connection on the left)
  • 5 x 1 ½ " socket (system connection on the right)
  • 2 x deflector plates
  • 2 x mitered pipe DN 40
  • 2 x return layer ducts
  • 5 x ½" sockets (standard sockets)
  • 1 x perforated sheet, 50%
  • 2 x 1" Socket (heat exchanger)

The system connection ports are spaced 100° apart.

Insulation Details

Material
Neodul®
Insulation color
Silver
Fire rating
B2 according to DIN 4102
Temperature Resistance
110 °C
ErP Class
B
ErP - Heat loss (W)
83 W

Insulation thickness of jacket (assembled): 130 mm, 110 mm gray EPS (0.032 W/mK), 20 mm polyester fiber fleece (0.040 W/mK)

Cover thickness 150 mm

  • 100 mm EPS, gray, 0.032 W/mK
  • 50 mm polyester fiber fleece 0.040 W/mK

Floor insulation made of high-density fleece

  • 50 mm polyester fiber fleece 0.033 W/mK

Dimensions with insulation

  • 1050 x 1790 (Ø x H) mm
Manufacturer
Juratherm GmbH
Match Code
JPSLR 825 V2, assembled, silver

Assembly consisting of

  • JPSLR Type 825 V2
  • Neodul Insulation Type 825
Weight
~256 kg
Tilt height
1740 mm
EAN13
4250659510443

Composition

Product video

JPSLR 825 in motion