Contact

buffer tank

JPSLR 500 · without insulation

JPSLR Type 500 V2 · Buffer tank with stratification charging system and 1 heat exchanger.

Item No. 157500

  • Tanks without insulation
nominal capacity
461
Ø without insulation
650 mm
Height
1,630 mm
Weight
133 kg
Tank 157500 In stock

As of Oct 28, 2026

Request for 157500

EAN 4250659510894

Average of JPSLR Type 500 V2

Dimensions and weights

H 1,630 Ø 650 17 18 14 11 8 5 2 16 13 10 7 4 1
Ø without insulation
650 mm
Height
1,630 mm
tilt height
1,665 mm
Weight
133 kg

Connections

Letters as shown in the illustration

Letter connection Height Size Thread Angle
1 Connection 1 Front socket 220 mm 1½" Female thread 17.63°
Connection 1 Rear socket 220 mm 1½" Female thread 117.63°
2 sensor sleeve 220 mm ½" Female thread 91.19°
18 Heating Return Return register (1.8 m²) 220 mm 1¼" Female thread 44.07°
4 Connection 2 Front socket 620 mm 1½" Female thread 17.63°
Connection 2 Rear socket 620 mm 1½" Female thread 117.63°
5 sensor sleeve 620 mm ½" Female thread 91.19°
17 Heating flow line Register Flow (1.8 m²) 660 mm 1¼" Female thread 44.07°
7 Connection 3 Front socket 840 mm 1½" Female thread 17.63°
Connection 3 Rear socket 840 mm 1½" Female thread 117.63°
8 sensor sleeve 840 mm ½" Female thread 91.19°
10 Connection 4 Front socket 1,220 mm 1½" Female thread 17.63°
Connection 4 Rear socket 1,220 mm 1½" Female thread 117.63°
11 sensor sleeve 1,220 mm ½" Female thread 91.19°
13 Connection 5 Front socket 1,390 mm 1½" Female thread 17.63°
Connection 5 Rear socket 1,390 mm 1½" Female thread 117.63°
14 sensor sleeve 1,390 mm ½" Female thread 91.19°
16 Top connection Top connection (L=50) 1,630 mm 1½" Female thread 0°

Technical Specifications

Volume

nominal capacity
461

heat exchanger

Heat exchanger Bottom Surface
1.8 m²
WT Content at the bottom
12.6

Print

Heat exchanger Pressure drop at the bottom
159 mbar
Operating pressure of storage tanks
4.5 bar
Test pressure of the storage tank
7.8 bar
Max. Pressure heat exchanger
6 bar

specification text

ENERGY BUFFER TANK with 1 heat exchanger and a stratification charging system, resulting in significantly improved stratification behavior

Buffer tank for all hot water central heating systems. Suitable for: solid fuel and oil-fired boilers, heat pumps, solar systems, and gas or electric instantaneous water heaters. Manufactured from high-quality S235JR steel in accordance with EN 10025 and EC Directive 97/23/EC; exterior with anti-corrosion coating, interior left unfinished. Includes a sensor terminal strip for variable positioning of the sensors.

Nominal capacity
461 L
Operating pressure of storage tanks
4.5 bar
Test pressure of the storage tank
7.8 bar
Minimum pressure in the storage tank
+0 bar
Max. operating temperature
95°C
Min. temperature
20 °C
Heat exchanger Bottom Surface
1.8 m²
WT Content at the bottom
12.6 L
Heat exchanger Pressure drop at the bottom
159 mbar
Max. Pressure heat exchanger
6 bar

Features

  • 1 x 1½" socket (air vent)
  • 5 x 1 ½ " socket (system connection on the left)
  • 5 x 1 ½ " socket (system connection on the right)
  • 2 x deflector plates
  • 2 x mitered pipe DN 40
  • 2 x return layer ducts
  • 5 x ½" sockets (standard sockets)
  • 1 x perforated sheet, 50%
  • 2 x 1" Socket (heat exchanger)

The system connection ports are spaced 100° apart. Dimensions without insulation: 650 x 1630 (Ø x H) mm

Manufacturer
Juratherm GmbH
Match Code
JPSLR 500
Weight
~133 kg
Tilt height
1665 mm
EAN13
4250659510894

Product video