Contact

hygienic tank

EHWP 950 · Ecoline Vlies silver

Efficiency Class C

EHWP 950, assembled, silver · Includes 100 mm fleece insulation

Item No. 840454

  • Assembled tank
  • For heat pumps
  • Not included in the price list
heat loss
144 W
Standby loss
3.46 kWh/24 h
ErP Volume
956
Weight
188 kg
Tank 180950 Delivery time: approx. 4–8 weeks
Insulation 9724950 In stock
Total Delivery time: approx. 4–8 weeks

As of Oct 28, 2026

Request for 840454

EAN 4250659514748

Average of EHWP 950, assembled, silver

Dimensions and weights

H 2,220 Ø 990
Ø with insulation
990 mm
Ø without insulation
790 mm
Height including insulation
2,220 mm
Height without insulation
2,170 mm
tilt height
2,210 mm
Weight
188 kg
Insulation thickness
100 mm

Connections

No connections have been specified for this tank yet.

Technical Specifications

Volume

nominal capacity
875

heat exchanger

Stainless steel corrugated pipe surface
13.5 m²

Print

Operating pressure of storage tanks
3 bar
Max. Pressure EWW
6 bar
Max. Pressure heat exchanger
6 bar

insulation

Insulation thickness of the jacket (assembled)
100 mm
Insulation thickness of the jacket (raw)
115 mm
Insulation thickness of the lid
100 mm
Insulation color
silver
Lambda
0.0388 W/mK
Bulk density
1800 g/m²
Fire rating
B2 according to DIN 4102

Energy (ErP)

ErP Class
C
ErP - Heat loss (W)
144 W
ErP – Heat Loss (kWh)
3.46 kWh
ErP - Contents
956

specification text

High-Performance Hygienic Storage, including insulated layered storage tank without solar heat exchanger

Hygienic storage tank specially developed for high draw-off rates combined with low temperature differentials. Ideally suited for heat pumps thanks to special stratification channels.

Manufactured from S235JR quality steel in accordance with EN 10025 and EC Directive 97/23/EC; exterior with rust protection, interior untreated. Hot water using the flow-through principle with a V4A 1.4404 stainless steel corrugated pipe, including a sensor terminal strip for variable positioning of the sensors

Nominal capacity
875 L
Max. operating pressure of the storage tank
3 bar
Test pressure of the storage tank
4.5 bar
Minimum pressure in the storage tank
+0 bar
Max. operating temperature
95°C
Min. temperature
20 °C
Stainless steel corrugated pipe surface
13.5 m²
Max. Pressure EWW
6 bar
Max. Pressure heat exchanger
6 bar

Features

  • 1 x 1½" socket (air vent)
  • 4 x 2" sockets (system connection on the left)
  • 4 x 2" sockets (system connection on the right)
  • (System connection incl. layer guide channel
  • (for high flow rates)
  • 2 x 2" Socket (electric heater)
  • 2 x 1 ¼" socket (hot and cold water)
  • 2 x 1" Socket (heat exchanger)
  • 3 x ½" sockets (standard sockets)
  • 1x " socket (drain)

The system connection ports are spaced 90° apart.

Insulation Details

Material
Polyester fiber nonwoven
Insulation color
Silver
Insulation thickness of the jacket (assembled)
100 mm
Lambda
0.0388 W/mK
Fire rating
B2 according to DIN 4102
Temperature Resistance
110 °C
Bulk density
1800 g/m²
Includes 50 mm floor insulation
ErP Class
C
ErP - Heat loss (W)
144 W

Dimensions with insulation

  • 990 x 2220 (Ø x H) mm
Manufacturer
Juratherm GmbH
Match Code
EHWP 950 silver

Assembly consisting of

  • EHWP 950
  • Nonwoven insulation, Type 950
Weight
~188 kg
Tilt height
2210 mm
EAN13
4250659514748

Composition

Product video

EHWP 950 in motion